Daftar Produk

Hubungi kami

  • Beijing Tihoo Technology Co., Ltd.
  • +86 18501073979tianhao-caiqingqing@cabr-th.com
  • Gedung Komprehensif Jiankeyan, Jalan Timur Lingkar Ketiga Utara, Distrik Chaoyang, Beijing.
    Tanpa Judul-1
    X
    Tanpa Judul-1

    Peralatan pengujian kinerja pencahayaan jendela gedung MCG

    Kategori:

    Hubungi Sekarang

    Digunakan untuk menguji transmisi cahaya jendela bangunan, cocok untuk jendela bangunan yang terbuat dari berbagai bahan. Ini mencakup koefisien transmisi dan indeks transmisi warna dari bagian atas jendela atap dan pintu balkon, dan dapat mendeteksi koefisien transmisi dan indeks transmisi warna dari dinding tirai kaca pada saat yang bersamaan.

    1. standard of execution
    GB/T 11976-2015 Wisuda dan metode pengujian sifat pencahayaan alami untuk jendela eksternal.

    2. Main technical parameters
    Test items: transmittance T and color transmittance R.
    The testing device consists of light source room, light source, receiving room, specimen frame and testing instrument.

    Light room:
    The inner surface is diffusely reflected with low spectral selectivity and a reflection ratio greater than 0.8
    The illuminance on the surface of the specimen is greater than 1000lx, and the illuminance difference at each point is less than 1%
    The light source room shall be rectangular, with the opening area less than 10% of the indoor surface area

    light source:
    Electric light source with continuous spectrum, symmetrical arrangement and light control device are adopted
    The light source is powered by a stabilized voltage source, and its voltage fluctuation is no more than 0.5%
    The stability of the light source was checked according to the method described in appendix 1 of jjg247-1994
    The light source is specially designed to ensure that no direct light falls on the surface of the specimen

    Reception room:
    The inner surface is diffusely reflected with low spectral selectivity and a reflection ratio greater than 0.8
    The receiving chamber is a cube, and the opening area is less than 10% of the indoor surface area

    Specimen box:
    The thickness of the specimen frame is equal to the actual wall thickness
    The connection part between the specimen frame and the two-chamber opening is strictly sealed to ensure no light leakage

    Optical receiver:
    The optical receiver shall have a V() correction whose spectral response is consistent with the illumination efficiency of the international illumination commission's light vision spectrum
    The optical receiver has a cosine corrector, and the optical receiver meets the requirements of the first-level illuminometer specified by JJG245
    The optical receiver is uniformly arranged on the periphery and inner side of the opening of the receiving chamber, and the quantity is set according to the size

    Permintaan Pertanyaan

    Tentang kami

    Beijing Tihoo Technology Co, Ltd terutama mengembangkan, memproduksi dan menjual berbagai jenis bahan bangunan dan peralatan pengujian teknik. Dalam beberapa tahun terakhir, berbagai peralatan pengujian dengan hak kekayaan intelektual independen telah dikembangkan dan secara bertahap dipasarkan. Produk-produk yang telah diproduksi meliputi penghematan energi bangunan, pintu bangunan, jendela dan dinding tirai, bahan bangunan dan peralatan pengujian kota.

    Permintaan Penawaran