    MCG bygning vinduesbelysning ydeevne testudstyr

    Kategorier:

    Kontakt nu

    Anvendes til test af lystransmission af bygningsvinduer, velegnet til bygningsvinduer lavet af forskellige materialer. Den inkluderer transmittanskoefficienten og farvetransmissionsindekset for den øverste del af ovenlysvinduet og altandøren og kan samtidig detektere glasgardinvæggens transmissionskoefficient og farvetransmissionsindeks.

    1. standard of execution
    GB/T 11976-2015 Graduering og testmetode for dagslysegenskaber til udvendige vinduer.

    2. Main technical parameters
    Test items: transmittance T and color transmittance R.
    The testing device consists of light source room, light source, receiving room, specimen frame and testing instrument.

    Light room:
    The inner surface is diffusely reflected with low spectral selectivity and a reflection ratio greater than 0.8
    The illuminance on the surface of the specimen is greater than 1000lx, and the illuminance difference at each point is less than 1%
    The light source room shall be rectangular, with the opening area less than 10% of the indoor surface area

    light source:
    Electric light source with continuous spectrum, symmetrical arrangement and light control device are adopted
    The light source is powered by a stabilized voltage source, and its voltage fluctuation is no more than 0.5%
    The stability of the light source was checked according to the method described in appendix 1 of jjg247-1994
    The light source is specially designed to ensure that no direct light falls on the surface of the specimen

    Reception room:
    The inner surface is diffusely reflected with low spectral selectivity and a reflection ratio greater than 0.8
    The receiving chamber is a cube, and the opening area is less than 10% of the indoor surface area

    Specimen box:
    The thickness of the specimen frame is equal to the actual wall thickness
    The connection part between the specimen frame and the two-chamber opening is strictly sealed to ensure no light leakage

    Optical receiver:
    The optical receiver shall have a V() correction whose spectral response is consistent with the illumination efficiency of the international illumination commission's light vision spectrum
    The optical receiver has a cosine corrector, and the optical receiver meets the requirements of the first-level illuminometer specified by JJG245
    The optical receiver is uniformly arranged on the periphery and inner side of the opening of the receiving chamber, and the quantity is set according to the size

    Anmod om forespørgsel

    Om os

    Beijing Tihoo Technology Co., Ltd. udvikler, fremstiller og sælger hovedsageligt forskellige former for byggematerialer og teknisk testudstyr. I de senere år er en række forskellige testudstyr med uafhængige intellektuelle ejendomsrettigheder blevet udviklet og gradvist bragt på markedet. De produkter, der er sat i produktion, omfatter bygningsenergibesparelse, bygningsdøre, vinduer og gardinvægge, byggematerialer og kommunalt testudstyr.

    Anmod om et tilbud