1. Product introduction
适用于评价建筑材料在规定实验室条件下燃烧性能的试验。
2. standard of execution
GB/T2406-2008
GB/T5454-1997
3.Main technical parameters
1)Computer control and operation, meet the national standard power heating;
2)Test results (test report) can be printed and stored in the computer;
3)Power supply voltage: AC220V±10%, 50Hz, current <10A;
4)Stabilization time: rose from room temperature to 750℃<45min;
5)Temperature drift in the furnace: <2℃/10min;
6)Heating power: 800-1000w;
7)Temperature in the furnace (750±5) ℃, temperature drift within 10min ≤2℃;
8)Inner diameter of furnace tube 75mm±1mm, height 150mm±1mm, power 2kW;
9)Thermocouple: nickel-chrome-nickel-silicon armored thermocouple; Stainless steel;
10)Configuration and accessories: 1 computer, 1 test program software, 1 set of random accessories;
11)Computer control and data processing, automatically and accurately record the temperature required by standard 7.2.3, calculate the temperature rise and measurement time according to 8.1, and format and print the test results;
12)External dimensions of the equipment: length 1.2× width 0.8× height 1.5m; Equipment weight: 60kg.